STF-118804
本产品不向个人销售,仅用作科学研究,不用于任何人体实验及非科研性质的动物实验。
STF-118804图片
CAS NO:894187-61-2
规格:≥98%
包装与价格:
包装价格(元)
5mg电议
10mg电议
25mg电议
50mg电议
100mg电议
250mg电议
500mg电议

产品介绍
理化性质和储存条件
Molecular Weight (MW) 461.53
Formula C25H23N3O4S
CAS No. 894187-61-2
Storage-20℃ for 3 years in powder form
-80℃ for 2 years in solvent
Solubility (In vitro)DMSO: 61 mg/mL (132.16 mM)
Water: <1 mg/mL
Ethanol:
SMILES CodeO=C(NCC1=CC=CN=C1)C2=CC=C(C3=NC(CS(=O)(C4=CC=C(C)C=C4)=O)=C(C)O3)C=C2
SynonymsSTF 118804; STF118804; STF-118804
实验参考方法
In Vitro

In vitro activity: STF-118804 reduces the viability of B-ALL cell lines containing MLL chromosomal translations, with IC50 values in the low nanomolar range. In addition, leukemic samples from five pediatric ALL patients are also sensitive to STF-118804 in the low nanomolar range. STF-118804 induces leukemia MV411 cell apoptosis without antecedent cell cycle arrest.


Kinase Assay: The enzymatic activities of NAMPT and NMNAT are measured using in vitro kits and using the Two-Step Method per manufacturer’s instructions. Compounds, NAMPT and/or NMNAT enzymes, and their substrates are mixed and incubated at 30°C for 1 hour. Reagents for the indicator reaction (Wst-1) are then added, and absorbance is read at 450 nm every 5 min at 30°C on a Tecan Infinite M100 multimode plate reader.


Cell Assay: Human cell lines or lineage negative cord blood cells were seeded into 96-well plates (6×105 cells per milliliter). Compounds are added in increasing concentrations, and cells are incubated at 37°C/5% CO2 for 72 hours. To detect viability, CellTiter-Blue reagent is added at 1:10 dilution, and plates are incubated for 4 hours at 37°C/5% CO2 prior to reading on a Flexstation II 384 or a Synergy H1 reader at an excitation of 555 nm and emission detection of 590 nm. Cell viability is also measured by CellTiter-Fluor. The cell-permeable fluorogenic peptide substrate GF-AFC reagent is added at 1:2 dilution, and plates are incubated for 30 min at 37°C/5% CO2 prior to reading on a Synergy H1 reader at an excitation of 380 nm and emission detection of 505 nm. Cord blood cells are enumerated on a hemocytometer, and cell viability is assessed with trypan blue exclusion dye. Inhibitory concentration (IC50) is calculated using Prism software. Primary patient samples are plated in 96-well plates and treated with increasing concentrations of STF-118804 for 48 hours at 37°C in 5% CO2. WST-1 reagent is added to the culture medium (1:10 dilution), and absorbance is measured at 450 nm using a Bio-Rad model 680 microplate reader.

In Vivo STF-118804 (25 mg/kg twice daily, s.c.) improves survival in an orthotopic xenotransplant model of high-risk acute lymphoblastic leukemia, and effectively depletes leukemia-initiating cells
Animal model Orthotopic xenograft model of ALL transplanted with MV411 cells
Formulation & Dosage 20% [w/v] [2-hydroxypropyl]-γ-cyclodextrin/5% [v/v] DMSO;25 mg/kg twice daily; s.c.
ReferencesChem Biol. 2013 Nov 21;20(11):1352-63.