您好,欢迎来到化工原料网! [登录] [免费注册]
化工原料网
位置:首页 > 产品库 > JC-1
立即咨询
咨询类型:
     
*姓名:
*电话:
*单位:
Email:
*留言内容:
请详细说明您的需求。
*验证码:
 
JC-1
本产品不向个人销售,仅用作科学研究,不用于任何人体实验及非科研性质的动物实验。
JC-1图片
CAS NO:3520-43-2
包装与价格:
包装价格(元)
1mg电议
2mg电议
5mg电议
10mg电议
50mg电议

产品介绍
JC-1 (CBIC2) 是一种荧光亲脂性羰花青染料,用于测量线粒体膜电位。
Cas No.3520-43-2
别名CBIC2;JC1;JC 1
化学名5,6-dichloro-2-[(E)-3-(5,6-dichloro-1,3-diethylbenzimidazol-3-ium-2-yl)prop-2-enylidene]-1,3-diethylbenzimidazole;iodide
Canonical SMILESCCN1C2=CC(=C(C=C2[N+](=C1C=CC=C3N(C4=CC(=C(C=C4N3CC)Cl)Cl)CC)CC)Cl)Cl.[I-]
分子式C25H27Cl4IN4
分子量652.23
溶解度≥ 32.6 mg/mL in DMSO with gentle warming
储存条件Store at -20℃,protect from light
General tipsFor obtaining a higher solubility , please warm the tube at 37 ℃ and shake it in the ultrasonic bath for a while.
Shipping ConditionEvaluation sample solution : ship with blue ice
All other available size: ship with RT , or blue ice upon request
产品描述

JC-1 is a fluorescent lipophilic carbocyanine dye used to measure mitochondrial membrane potential.

JC-1 (2.5 μM) exposed to murine L1210 lymphoblasts, can be detected the presence of both cytoplasmic JC-1 monomer and mitochondrial J-aggregates in these cells. JC-1 fluorescence is usually excited by the 488 nm laser wavelength common in flow cytometers[1]. Fluorescent labeling of mitochondria with either JC-1 (1 μg/mL, 15 min), reveals that are distributed irregularly, resulting in regions of high and low mitochondrial content within astrocytes[2]. JC-1 has been shown to interact with α-synuclein at the acidic C-terminal region with a Kd of 2.6 μM. JC-1 itself does not accelerate the protein aggregation of α-synuclein in the absence of iron, insted, it decelerates the aggregation process by extending the lag phase approx[3]. JC-1 is avidly accumulated in sensitive K562 cells where it displays both a green cytoplasmic and red mitochondrial fluorescence. JC-1 is poorly accumulated in resistant K562 cells, which displays only a slight green fluorescence[4].

References:
[1]. A Perelman, et al. JC-1: alternative excitation wavelengths facilitate mitochondrial membrane potential cytometry. Cell Death Dis. 2012 Nov 22;3:e430.
[2]. Vera C. Keil, et al. Ratiometric high-resolution imaging of JC-1 fluorescence reveals the subcellular heterogeneity of astrocytic mitochondria. Pflügers Archiv - European Journal of Physiology. 2011,462(5): 693-708.
[3]. Jung-Ho LEE, In-Hwan LEE, Young-Jun CHOE, et al. Real-time analysis of amyloid fibril formation of α-synuclein using a fibrillation-state-specific fluorescent probe of JC-1. Biochem. J. 2009, 418:311-323.
[4]. Salvioli S, et al. JC-1, but not DiOC6(3) or rhodamine 123, is a reliable fluorescent probe to assess delta psi changes in intact cells: implications for studies on mitochondrial functionality during apoptosis. FEBS Lett. 1997 Jul 7;411(1):77-82.